Cases

Industrial Automation,Frequency Inverters,Energy Regeneration,Electric Mobility (EV),Renewable Energy (Solar, Wind),Oil & Power Energy
HomeCasesLoad Reactor for testing various performance parameters of electric vehicle motor drives

Load Reactor for testing various performance parameters of electric vehicle motor drives

Tags:
Share to:

Sikes load reactor successfully installed and operated in a large electric vehicle test center in China for testing the EV motor drives.

sikes high-precision load reactor was successfully installed and operated in a large electric vehicle test center in China. They are mainly used to test various performance parameters of EV motor drives.One or more high-precision load reactors work to be as an inductive load bank to simulate  a combined electric vehicle. This purely inductive load saves a lot of energy for long-term continuous testing.

Load bank parameters:

Circle time: 300s
600A for 270s
900A for 30s
1200A Unsaturated

Chracteristics:
1. Capacity: 42.1kvar;
2. Working frequency: 500Hz
3. Voltage range: 380V;
4. Insulation class: F / H;
5. Load features: Inductive load;
6. Ambient temperature: -10 ° C to +50 ° C;
7. Altitude: ≤3000m.
8. Weight:255kg

Resistive-Inductive Load Bank for testing various performance parameters of electric vehicle motor drives
Previous: Resistive-Inductive Load Bank for testing various performance parameters of electric vehicle motor drives 1 month ago
Sikes Harmonic Filter were installed in New World Millennium Hong Kong Hotel
Next: Sikes Harmonic Filter were installed in New World Millennium Hong Kong Hotel 1 month ago
SIKES Editor
View All Products Quick Filter
Products You May Like
Our most popular and best-selling items